Portable Charge (Type A)
ONE1Q011087
- Code and Plug (Code set)
- Control Box
- Charging Cable and Charging Connector
Portable Charge can be used when AC Charge or DC Charge is not available by using household electricity.
ONE1043060N
- Plug
- Electric Outlet
Plug
-
Check the rated current of the electric outlet prior to connecting the plug to the outlet.
-
Connect the plug to a household electric outlet.
-
Check the display window on the control box.
ONX4EPHQ011024L
-
Press the button (1) on the front of the control box for 2 to 8 seconds to adjust the charge level. (Refer to charging cable type and example for setting the charge level.)
-
The charge level on the display window of the control box changes every time you press the button (1).
-
When setting the charge level is complete, start charging according to the portable charge instructions.
* Example for setting the ICCB charge level
The example is only for reference and may vary according to the surrounding environment.
|
Outlet current |
ICCB charge level |
Control box display window |
|
14-16 A |
12 A |
|
|
13-12 A |
10 A |
|
|
11-10 A |
8 A |
|
|
9-8 A |
6 A |
Please make sure that charge level selection matches the capacity of your circuit breaker to avoid blown fuse.
ONE1043060N
- Plug
- Electric Outlet
-
Connect the plug to a household electric outlet.
ONX4EPHQ011005L
-
Check if the power lamp (green) illuminates on the control box.
-
Depress the brake pedal and apply the parking brake.
-
Turn OFF all switches, shift to P (Park), and turn OFF the vehicle.
If charging is initiated without the gear in P (Park), the charging will start after the gear is automatically shifted to P (Park).
ONE1Q011040
-
Open the charging door.
For more details, refer to ‘Electric Charging Door’ in this chapter.
If you cannot open the charging door due to freezing weather, tap lightly or remove any ice near the charging door. Do not try to forcibly open the charging door.
-
Open the protection caps of the charging connector and the charging plug. Check if there are any foreign substances or dust.
-
Hold the charging connector handle and connect it to the vehicle charging inlet. Push the connector all the way in. If the charging connector and charging terminal are not connected properly, this may cause a fire.
Locking Charging Cable
Select Settings > ECO Vehicle > Charging Connector Locking Mode in the infotainment. The charging connector is locked in the inlet at a different period according to which mode is selected.
-
Always mode : The connector locks when the charging connector is plugged into the charging inlet.
-
While charging mode : The connector locks when charging starts.
For more details, refer to “Locking Charging Cable” in this chapter.
ONX4EPHQ011006L
-
-
Charging starts automatically (charging lamp illuminates).
ONE1Q011041
-
Check if the charging indicator light (
) of the high voltage battery on the instrument cluster is turned ON. Charging is not active when the charging indicator light (
) is OFF.When the charging connector is not connected properly, reconnect the charging cable to charge it again.
To control the temperature of the high voltage battery while charging, the air conditioning is used to cool down the battery. This may generate noise or vibration from operation of the air conditioning compressor and cooling fan, but it is a normal condition when charging the high voltage battery. Also, the air conditioning’s performance may be degraded due to operation of the cooling system to charge the high voltage battery. This is a normal condition.
Even though charging is possible with the Start/Stop button in the ON/START position, for you safety, start charging when the Start/Stop button is in the OFF position and the vehicle shifted to P (Park). After charging has started, you can use electrical components such as the radio by pressing the Start/Stop button to the START or ON position.
During charging, the gear cannot be shifted from P (Park) to any other gear.
ONE1Q011058E
-
After charging has started, the estimated charging time is displayed on the instrument cluster for about 1 minute.
If you open the driver seat door while charging, the estimated charging time is also displayed on the instrument cluster for about 1 minute. When scheduled charging or scheduled air conditioner/heater is set, the estimated charging time is displayed as “--” .
Depending on the condition and durability of the high voltage battery, charger specifications, and ambient temperature, the time required for charging the battery may vary.
When charging the high voltage battery, the charge level can be checked from outside the vehicle.
For more details, refer to ‘Charge indicator lamp for electric vehicle’ in this chapter.
ONX4EPHQ011008L
|
Indicator |
Details |
|
|
POWER |
|
On : Power on |
|
CHARGE |
|
On : Charge Blink : Current limit due to high plug temperature or high internal temperature |
|
FAULT |
|
Blink : Charging interrupted |
|
Indicator |
Details |
|||
|
Error code |
|
On : Error while charging/ Error during self-diagnosis |
||
|
Error code |
Item |
Cause |
||
|
E1 |
Control Pilot communication |
Vehicle communication error |
||
|
E2 |
Leakage |
Current leakage |
||
|
E3 |
Charger error |
|||
|
E4 |
Plug temperature |
Plug overtemperature warning |
||
|
E5 |
Plug temperature failure |
|||
|
E6 |
Charger error |
|||
|
E7 |
Overcurrent |
Charging overcurrent warning |
||
|
E8 |
Internal temperature |
Charger overheating |
||
|
E9 |
Charger error |
|||
|
F1 |
Relay fusion |
Charger error |
||
|
F2 |
Ground Monitoring/Interrupt |
Poor grounding of outlet |
||
|
F3 |
Switched mode power supply power failure |
Switched mode power supply error (voltage failure) |
||
|
F4 |
Switched mode power supply error (abnormal voltage) |
|||
|
F5 |
Control Pilot voltage error |
Control Pilot (-) voltage error |
||
|
F6 |
Control Pilot (+) voltage error |
|||
|
F7 |
Temperature sensor error |
Plug temperature sensor error |
||
|
F8 |
PCB internal temperature sensor error |
|||
|
CHARGE LEVEL |
|
12 A |
||
|
10 A |
|||
|
8 A |
|||
|
6 A |
|||
|
The charging current changes whenever the button (1) is pressed for less than 1 sec with the charger plugged into an electrical outlet but not the vehicle. |
* The control box
|
|||
ONX4EPHQ011005L
-
Charging connector plugged into vehicle (POWER Green ON)
-
Plug connected to an electric outlet (POWER Green ON)
ONX4EPHQ011006L
While charging
-
Charge indicator (POWER Green ON / CHARGE Blue ON)
-
Charging current
ONX4EPHQ011009L
Before plugging charging connector into vehicle (POWER Green ON, FAULT Red blink)
-
Abnormal temperature
-
ICCB (In-Cable Control Box) failure
Contact an authorized HYUNDAI dealer.
ONX4EPHQ011009L
Plugged into vehicle (POWER Green ON, FAULT Red Blink)
-
Diagnostic device failure
-
Current leakage
-
Abnormal temperature
Contact an authorized HYUNDAI dealer.
ONX4EPHQ011010L
-
Leakage current failure (POWER Green ON, FAULT Red Blink)
-
After disconnecting and reconnecting the power plug, press and release the button for 2 seconds or longer to clear the error.
Contact an authorized HYUNDAI dealer.
ONX4EPHQ011011L
Power saving mode
-
7-segment display is turned off if there is no status change for more than 1 minute.
ONE1Q012044N
-
Hold the charging connector handle and pull it out.
To prevent charging cable theft, the charging connector cannot be disconnected from the inlet when the doors are locked or the charging connector is in the LOCK mode. Unlock all doors to disconnect the charging connector from the inlet.
However, if the vehicle is in the charging connector AUTO mode, the charging connector automatically unlocks from the inlet when charging is completed.
If you attempt to disconnect the charging connector without pressing the release button, the connector and the inlet may be damaged.
For more details, refer to “Charging Connector AUTO/ LOCK Mode” in this chapter.
If the release button does not work even after the all doors are unlocked, pull the emergency lift cable in the motor room and press the release button in the connector to disconnect it from the vehicle. If the release button still does not work, consult an authorized HYUNDAI dealer.
-
Make sure to completely close the charging door.
ONE1Q012103N
- : Plug
- : Electric Outlet
-
Disconnect the plug from the household electric outlet. Do not pull the cable when disconnecting the plug.
-
Close the protection caps of the charging connector and the charging plug to protect them from foreign substances.
-
If the personal charging connector is used, store the connector in the cable compartment.
-
Use the portable charger that is certified by HYUNDAI Motors.
-
Do not try to repair, disassemble, or adjust the portable charger.
-
Do not use an extension cord or adapter.
-
Stop using immediately when failure occurs.
-
Do not touch the plug and charging connector with wet hands.
-
Do not touch the terminal part of the AC charging connector and the AC charging inlet on the vehicle.
-
Do not connect the charging connector to voltage that does not comply with regulations.
-
Do not use the portable charger if it is worn out, exposed, or there exists any type of damage on the portable charger.
-
If the ICCB case and AC charging connector is damaged, cracked, or the wires are exposed in any way, do not use the portable charger.
-
Do not let children operate or touch the portable charger.
-
Keep the control box free of water.
-
Keep the normal charging connector or plug terminal free of foreign substances.
-
Do not step on the cable or cord. Do not pull the cable or cord and do not twist or bend it.
-
Do not charge when there is lightning.
-
Do not drop the control box or place a heavy object on the control box.
-
Do not place an object that can generate high temperatures near the charger when charging.
-
Charging with the worn out or damaged household electric outlet can result in a risk of electric shock. If you have doubts about the condition of a household electric outlet, have it checked by a licensed electrician.
-
Stop using the portable charger immediately if the household electric outlet or any components is overheated or you notice burnt odors.